Original Title
The transition of the water steam through the composition of the diffusive closed circumferential wall of the wooden house with the proper and improper realization of vapor barrier
Type
conference paper
Language
English
Original Abstract
The research is focused on measuring of the diffusion of moisture by composition of the diffusive closed circumferential wall of the wooden house with the proper and improper realization of the vapor barrier. To perform this research the experimental wooden house EXDR1 is going to be used. The wall, which would be the validation of measurement, is designed as a closed diffusion. The aim of this research is to compare the measurement results. The measured values of humidity probes are going to be used for the comparison. These probes are going to be located in place of a wooden post and in the field between the posts and the temperature-humidity sensors that are going to be installed only in the field between the posts. Thus, placing the probes to measure humidity of wooden post and the temperature-humidity sensors are going to measure the humidity and the temperature of with the proper and improper realization of vapor barrier (foil) for interior moisture to simulate processes normally happening inside residential buildings with adjustment of pressure in the measured room.
Keywords
The transition of the water steam, the diffusive closed circumferential wall, the vapor barrier, the humidity probe, the temperature-humidity sensor
Authors
UVIZLOVÁ, M.; BEČKOVSKÁ, T.
RIV year
2014
Released
17. 2. 2014
Publisher
Trans Tech Publications
Location
Switzerland
ISBN
1022-6680
Periodical
Advanced Materials Research
Year of study
899
Number
State
Swiss Confederation
Pages from
446
Pages to
449
Pages count
4
BibTex
@inproceedings{BUT102354, author="Martina {Procházková Uvizlová} and Tereza {Bečkovská}", title="The transition of the water steam through the composition of the diffusive closed circumferential wall of the wooden house with the proper and improper realization of vapor barrier", year="2014", journal="Advanced Materials Research", volume="899", number="2014", pages="446--449", publisher="Trans Tech Publications", address="Switzerland", doi="10.4028/www.scientific.net/AMR.899.446", issn="1022-6680" }