Original Abstract

Creating of waterproofing screens in building structure is nowadays one of the most widespread technology of redevelopment of wet and old masonry. Especially for old or damaged structures which would not withstand any other, more damaging, type of treatment is this method ideal. One of the biggest advantages of this method is its quick and relatively easy application, excellent efficiency and low impact on buildings statics. This articles main object is observing penetration rate and final functionality of hydroinsulating injection gels in sandstone building materials.

Keywords

waterproofing gels, injection screens, high temperature

Authors

MELICHAR, J.; DOHNÁLEK, P.; DROCHYTKA, R.

RIV year

2015

Released

20. 4. 2015

Publisher

Trans Tech Publications

Location

Švýcarsko

ISBN

978-3-03835-452-9

Book

Advanced materials research

ISBN

1022-6680

Periodical

Advanced Materials Research

Year of study

1100

Number

10.4028

State

Swiss Confederation

Pages from

189

Pages to

192

Pages count

4

BibTex

@inproceedings{BUT113090,
  author="Jindřich {Melichar} and Pavel {Dohnálek} and Rostislav {Drochytka}",
  title="Testing of waterproofing gels penetration rate while exposure to higher temperature",
  booktitle="Advanced materials research",
  year="2015",
  journal="Advanced Materials Research",
  volume="1100",
  number="10.4028",
  pages="189--192",
  publisher="Trans Tech Publications",
  address="Švýcarsko",
  doi="10.4028/www.scientific.net/AMR.1100.189",
  isbn="978-3-03835-452-9",
  issn="1022-6680"
}