Přístupnostní navigace
E-application
Search Search Close
Publication detail
ŠTIGLER, J. KOZÁK, J. SOUKUP, L. RUDOLF, P.
Original Title
Test Well CFD Analysis
Type
summary research report - contract. research
Language
English
Original Abstract
There is industrial demand to investigate reasons for creation of swirl at pump inlet and dependencies on its intensity. Victor Kaplan’s Department of Fluid Engineering was asked to make a simulation of flow in the test well and effect of the test well configuration and the discharge pipe diameter on velocity field and pre-swirl intensity at pump inlet. Existing test well is commonly used for testing pumps of flow rates up to 4300 m3/h without any problems. To verify the effect of discharge pipe were chosen three different diameters of the pipe: 800 mm, 1100 mm and 1400mm. The test well will be investigated in original configuration with niches and without the niches. Overall, there will be done six different simulations and they will be compared. The main task is to confirm or disprove usability of the test well for testing vertical pumps of flow rates up to 10000 m3/h. It is important to mention that the pump impeller is not included in the CFD analysis. Only geometry of the well, inlet and discharge pipes are considered.
Keywords
Fluid flow in test well, swirl at pump inlet,
Authors
ŠTIGLER, J.; KOZÁK, J.; SOUKUP, L.; RUDOLF, P.
Released
30. 4. 2014
Publisher
Department of Fluid Engineering, Energy Institute, Faculty of Mechanical Engineering, Brno University of Technology
Location
Brno, Czech Republic
Pages from
1
Pages to
77
Pages count
BibTex
@misc{BUT113350, author="Jaroslav {Štigler} and Jiří {Kozák} and Lubomír {Soukup} and Pavel {Rudolf}", title="Test Well CFD Analysis", year="2014", pages="1--77", publisher="Department of Fluid Engineering, Energy Institute, Faculty of Mechanical Engineering, Brno University of Technology", address="Brno, Czech Republic", note="summary research report - contract. research" }