Přístupnostní navigace
E-application
Search Search Close
Publication detail
BLAHA, M. PROVAZNÍK, I. VESELÝ, Z. NOVÁKOVÁ, M.
Original Title
Influence of Voltage-Sensitive Dye on ECG Parameters
Type
conference paper
Language
English
Original Abstract
This paper presents methods for analysis of changes in ECG signals caused by application of voltage-sensitive dye (VSD). The signals were experimentally recorded from isolated guinea pig hearts prior optical recording. The analysis was performed in time and time-frequency space with focus on changes occurring in QRS complex. The influence of VSD was examined in a 70-second interval after VSD application in detail and then periodically for the following ten minutes. The results were compared to those from traditional R-R interval analysis.
Keywords
Voltage-sensitive dye, ECG, R-R interval, wavelet transform
Authors
BLAHA, M.; PROVAZNÍK, I.; VESELÝ, Z.; NOVÁKOVÁ, M.
RIV year
2004
Released
1. 1. 2004
Publisher
University of Southampton
Location
Valletta, Malta
ISBN
0-7803-8894-1
Book
MEDSIP 2004, 2nd International Conference on Advances in Medical Signal and Information Processing
Pages from
83
Pages to
86
Pages count
4
BibTex
@inproceedings{BUT11429, author="Milan {Blaha} and Valentine {Provazník} and Zbyněk {Veselý} and Marie {Nováková}", title="Influence of Voltage-Sensitive Dye on ECG Parameters", booktitle="MEDSIP 2004, 2nd International Conference on Advances in Medical Signal and Information Processing", year="2004", pages="83--86", publisher="University of Southampton", address="Valletta, Malta", isbn="0-7803-8894-1" }