Original Abstract

The paper discusses some practical problems occurring at ISO 10816-1 application in technical practice. Technical diagnosticians find out frequently that the zone boundaries proposed by the standard are not sensitive adequately to the changes in vibrations during operation resulting from a change of technical condition of the machine. The principle of statistical determination of individual operational limits from the measured overall level of RMS vibration velocity (overall level) with utilization of statistical regulation of individual values is also described in the paper. The alarm limit for the overall level (boundary between the B and C zones) in the range 10 Hz to 1,000 Hz is specified in the paper on the basis of measuring of vibrations on the electric motor of Bosch Rexroth hydraulic unit.

Keywords

operational limits; vibration diagnostics; zones boundary

Authors

JANKOVÝCH, R.; BUDÍK, T.; HAMMER, M.

RIV year

2015

Released

21. 9. 2015

Publisher

Springer International Publishing AG Switzerland

Location

Spolková republika Německo

ISBN

2194-5357

Periodical

Advances in Intelligent Systems and Computing

Year of study

1

Number

393

State

Swiss Confederation

Pages from

13

Pages to

18

Pages count

6

URL

BibTex

@article{BUT118087,
  author="Róbert {Jankových} and Tomáš {Budík} and Miloš {Hammer}",
  title="Operational Limits in Vibration Diagnostics",
  journal="Advances in Intelligent Systems and Computing",
  year="2015",
  volume="1",
  number="393",
  pages="13--18",
  doi="10.1007/978-3-319-23923-1",
  issn="2194-5357",
  url="http://www.springer.com/series/11156"
}