Check valve slam analysis in pumping station

HIMR, D. HABÁN, V. DOKOUPIL, P.

Original Title

Check valve slam analysis in pumping station

Type

conference paper

Language

English

Original Abstract

Pumping station supplies water for technological process. The check valve in the station was replaced with a new one. The regular test of black out discovered the high pressure pulsations accompanied with noticeable pipeline movement of discharge pipe. It was caused by late check valve closing, probably, when the back flow reached the highest possible velocity. This statement was supported with analysis of results of pressure measurement near the check valve and with a numerical simulation of the flow in the pipeline system.

Keywords

water hammer, check valve

Authors

HIMR, D.; HABÁN, V.; DOKOUPIL, P.

Released

28. 3. 2016

Publisher

EDP Sciences

ISBN

2100-014X

Periodical

EPJ Web of Conferences

Year of study

114

Number

2016

State

French Republic

Pages from

1

Pages to

6

Pages count

6

URL

Full text in the Digital Library

BibTex

@inproceedings{BUT123443,
  author="Daniel {Himr} and Vladimír {Habán} and Pavel {Dokoupil}",
  title="Check valve slam analysis in pumping station",
  booktitle="EPJ Web of Conferences",
  year="2016",
  journal="EPJ Web of Conferences",
  volume="114",
  number="2016",
  pages="1--6",
  publisher="EDP Sciences",
  doi="10.1051/epjconf/201611402038",
  issn="2100-014X",
  url="http://www.epj-conferences.org/articles/epjconf/abs/2016/09/epjconf_efm2016_02038/epjconf_efm2016_02038.html"
}