ŠKODA, J. SUMEC, S. BAXANT, P. MOTYČKA, M.
Original Title
Influence of background luminance on UGR result
Type
conference paper
Language
English
Original Abstract
The article describes UGR measurement with luminance analyzer and discusses overall impact of background luminance on the calculation result. Background luminance, defined as 2π, causes a problem if the luminance is on the periphery of the visual field. Another complication is that the position index is defined only for the upper half of the view. This causes a complication in glare measurements of luminaires in the lower part of the view. The article attempts to summarize possible variations in luminance analyzer measurements.
Keywords
UGR; luminance; discomfort glare
Authors
ŠKODA, J.; SUMEC, S.; BAXANT, P.; MOTYČKA, M.
Released
13. 9. 2016
ISBN
978-1-5090-3304-1
Book
VI IEEE Lighting Conference of the Visegrad Countries LUMEN V4 - Proceedings
Pages from
32
Pages to
35
Pages count
4
URL
https://ieeexplore.ieee.org/document/7745511
BibTex
@inproceedings{BUT128135, author="Jan {Škoda} and Stanislav {Sumec} and Petr {Baxant} and Martin {Motyčka}", title="Influence of background luminance on UGR result", booktitle="VI IEEE Lighting Conference of the Visegrad Countries LUMEN V4 - Proceedings", year="2016", pages="32--35", doi="10.1109/LUMENV.2016.7745511", isbn="978-1-5090-3304-1", url="https://ieeexplore.ieee.org/document/7745511" }