Original Abstract

For a design of the volume of the rainfall infiltration facility, the coefficient of infiltration is determined by an infiltration test. The use of the coefficient of infiltration brings certain uncertainties into the solution, arising from different conditions in carrying out the infiltration test and in operating a real infiltration facility. In this study an analysis is carried out of factors that influence the process of infiltration and related uncertainties influencing the determination of the storage volume of the infiltration facility. The effect of the individual factors on the design of the infiltration facility was analyzed using numerical simulations by the software HYDRUS-2D and expressed using partial reliability factors. For their determination the nomographs were set up by extensive numerical computations.

Keywords

infiltration facility, coefficient of infiltration, limit states, reability factors

Authors

DUCHAN, D.; ŘÍHA, J.

Released

4. 5. 2016

Publisher

Mendel University in Brno

Location

Brno, CZ

ISBN

1211-8516

Periodical

Acta Universitatis Agriculturae et Silviculturae Mendelianae Brunensis

Year of study

64

Number

5

State

Czech Republic

Pages from

1483

Pages to

1494

Pages count

12

URL

Full text in the Digital Library

BibTex

@article{BUT129393,
  author="David {Duchan} and Jaromír {Říha}",
  title="Hydraulic design of storm water infiltration facility including uncertainties",
  journal="Acta Universitatis Agriculturae et Silviculturae Mendelianae Brunensis",
  year="2016",
  volume="64",
  number="5",
  pages="1483--1494",
  doi="10.11118/actaun201664051483",
  issn="1211-8516",
  url="http://acta.mendelu.cz/artkey/acu-201605-0007_hydraulic-design-of-stormwater-infiltration-facility-including-uncertainties.php"
}