Publication detail

TID in-situ measurement of temperature coefficient of various commercial voltage references

HOFMAN, J. HÁZE, J. SHARP, R.

Original Title

TID in-situ measurement of temperature coefficient of various commercial voltage references

Type

conference paper

Language

English

Original Abstract

this work presents results of a total ionising dose experiment, during which commercial voltage references were irradiated and measured under different bias conditions using an in-situ technique. The automated test system allowed the output voltage of the voltage references to be measured at various temperatures during irradiation to 100 krad(Si) and the subsequent 7 day period of annealing.The experimental results obtained allow improved insight into total ionising dose induced degradation of data acquisition systems for space applications. The results show that the temperature coefficient of selected commercial voltage references significantly changes (increases) with TID. Therefore these devices can be used for data acquisition systems only on board LEO missions like CubeSats, which are typically exposed to a limited radiation dose.

Keywords

voltage reference, bandgap, buried Zener diode, data acquisition, A/D converter, TID test, in-situ, temperature coefficient, automated test equipment, test methods

Authors

HOFMAN, J.; HÁZE, J.; SHARP, R.

Released

4. 10. 2017

Publisher

IEEE

ISBN

9781509002337

Book

Radecs 2017 proceedings

Pages from

459

Pages to

462

Pages count

4

URL

BibTex

@inproceedings{BUT140351,
  author="Jiří {Hofman} and Jiří {Háze} and Richard {Sharp}",
  title="TID in-situ measurement of temperature coefficient of various commercial voltage references",
  booktitle="Radecs 2017 proceedings",
  year="2017",
  pages="459--462",
  publisher="IEEE",
  doi="10.1109/RADECS.2017.8696249",
  isbn="9781509002337",
  url="https://ieeexplore.ieee.org/document/8093206"
}