Original Abstract
Within a flow measurement and mapping chamber there is an extreme static pressure stability required to maintain static environmental conditions around the main center axis where all dynamic measurements and mapping take place. To be able to achieve such accurate pressure control a very accurate pressure measurement is required. This article aims at the use of a strain gauge for precise static pressure measurement within a flow measurement and mapping chamber.
Keywords
ANSYS Fluent, Electron microscopy, Pressure gauge, SolidWorks
Authors
Released
26. 8. 2018
Publisher
Brno University of Technology
Location
Brno
ISBN
978-80-214-5651-8
Book
Advanced Batteries Accumulators and Fuel Cells – 19th ABAF
Edition
19
Edition number
1
Pages from
145
Pages to
147
Pages count
3
BibTex
@inproceedings{BUT149605, author="Robert {Bayer}", title="Static pressure measurement within a flow measurement and mapping chamber", booktitle="Advanced Batteries Accumulators and Fuel Cells – 19th ABAF", year="2018", series="19", number="1", pages="145--147", publisher="Brno University of Technology", address="Brno", isbn="978-80-214-5651-8" }