Publication detail

Combined Pinch and exergy numerical analysis for low temperature heat exchanger network

Hamsani, M.N. Walmsley, T.G. Liew, P.Y. Wan Alwi, S.R.

Original Title

Combined Pinch and exergy numerical analysis for low temperature heat exchanger network

Type

journal article in Web of Science

Language

English

Original Abstract

To reduce the dependence on fossil fuel, Process Integration and energy efficiency are crucial in chemical process industry to minimise the consumption of fossil fuels and electricity demand through Heat Exchanger Network (HEN). Pinch Analysis is well established to optimal HEN design to maximize the energy recovery in a process. The stream matches for energy recovery in HEN is important to ensure the temperature potential is not wasted, which the temperature potential could be converted into mechanical work. Therefore, Exergy Analysis has been introduced to work with Pinch Analysis, which ensure the heat recovery stream matches with appropriate temperature differences to minimise the work potential (exergy) loss. This paper demonstrates how Pinch Analysis and Exergy Analysis is simultaneously applied to determine exergy targets (rejection, requirement and avoidable losses) in low temperature HEN. A novel numerical tool known as Exergy Problem Table Algorithm (Ex-PTA), is proposed in this paper as a numerical method to the conventional graphical representation in Extended Pinch Analysis and Design (ExPAnD) method. The proposed tool produces more realistic and achievable results. The net shaft work requirement of the refrigeration system is also determined together with the system COP. This paper explored the effect of setting heat exchangers' minimum approach temperature (ΔTmin) on the exergy targets for low temperature HEN design. The external utility requirement and unavoidable exergy losses increased with ΔTmin, while avoidable exergy losses and energy recovery reduced with respect to ΔTmin. The net power requirement of the system increased with the ΔTmin increment, however, the system COP reduced due to higher increment rate of compression compared to expansion work generation. The optimal ΔTmin was determined at 2 °C for heat recovery system in the case study based on super-targeting approach, which considers the total annualized cost, operating cost and capital cost

Keywords

Exergy analysis; Heat exchanger network; Low temperature; Pinch analysis; Process integration; Chemical industry; Computer system recovery; Costs; Energy efficiency; Exergy; Fossil fuels; Heat exchangers; Numerical methods; Recovery; Refrigeration; Temperature; Waste heat; Exergy Analysis; Chemical analysis; algorithm; design; electricity; energy efficiency; heat transfer; mathematical analysis

Authors

Hamsani, M.N.; Walmsley, T.G.; Liew, P.Y.; Wan Alwi, S.R.

Released

15. 6. 2018

Publisher

Elsevier Ltd

ISBN

0360-5442

Periodical

Energy

Year of study

153

Number

153

State

United Kingdom of Great Britain and Northern Ireland

Pages from

100

Pages to

112

Pages count

13

BibTex

@article{BUT151454,
  author="Hamsani, M.N. and Walmsley, T.G. and Liew, P.Y. and Wan Alwi, S.R.",
  title="Combined Pinch and exergy numerical analysis for low temperature heat exchanger network",
  journal="Energy",
  year="2018",
  volume="153",
  number="153",
  pages="100--112",
  doi="10.1016/j.energy.2018.04.023",
  issn="0360-5442"
}