Laser spot overlap in scanning laser ablation ICP-MS analysis: Impact on analytical signal and properties of the generated aerosol

HOLÁ, M. SALAJKOVÁ, Z. GREGAR, F. ONDRÁČEK, J. PAVLIŇÁK, D. ŠPERKA, P. HRDLIČKA, A. KAISER, J. KANICKÝ, V.

Original Title

Laser spot overlap in scanning laser ablation ICP-MS analysis: Impact on analytical signal and properties of the generated aerosol

Type

journal article in Web of Science

Language

English

Original Abstract

The aim of this study was to determine whether the degree of pulse overlap affects the analytical response of LAICP-MS when utilized in scanning mode. The investigation focused not only on the analytical signal but also on the properties of the generated aerosol and the morphology of ablation craters. Ablation was carried out using a nanosecond ablation system on single-element samples of metals and metalloids, specifically Cr, Hf, Sb, Si, Ta, and W. Pure single-element standards were selected to eliminate elemental fractionation and ensure the chemical composition of the generated aerosol was consistent across all particle sizes. The effect was studied on the surfaces of the samples prepared in various ways, including polished and two types of roughened finishes. It was found that the degree of laser pulse overlap significantly influences the quantity of generated particles, their size, and consequently the measured analytical signal, altering it by tens of percent. Slightly different properties were observed in the groups of metal and metalloid samples. For metals, an increasing overlap of pulses resulted in a decrease in the analytical signal across all types of surfaces. For metalloids, the results were different on polished surfaces. The study shows that adjusting the pulse overlap by combining the scan speed and laser repetition rate can have a significant effect on the LA-ICP-MS analysis results.

Keywords

Laser ablation; LA-ICP-MS; Scanning mode; Material science

Authors

HOLÁ, M.; SALAJKOVÁ, Z.; GREGAR, F.; ONDRÁČEK, J.; PAVLIŇÁK, D.; ŠPERKA, P.; HRDLIČKA, A.; KAISER, J.; KANICKÝ, V.

Released

1. 9. 2024

Publisher

PERGAMON-ELSEVIER SCIENCE LTD

Location

OXFORD

ISBN

1873-3565

Periodical

SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY

Year of study

219

Number

106999

State

United Kingdom of Great Britain and Northern Ireland

Pages count

13

URL

BibTex

@article{BUT189405,
  author="Markéta {Holá} and Zita {Salajková} and Filip {Gregar} and Jakub {Ondráček} and David {Pavliňák} and Petr {Šperka} and Aleš {Hrdlička} and Jozef {Kaiser} and Viktor {Kanický}",
  title="Laser spot overlap in scanning laser ablation ICP-MS analysis: Impact on analytical signal and properties of the generated aerosol",
  journal="SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY",
  year="2024",
  volume="219",
  number="106999",
  pages="13",
  doi="10.1016/j.sab.2024.106999",
  issn="1873-3565",
  url="https://www.sciencedirect.com/science/article/pii/S0584854724001435?via%3Dihub"
}