Přístupnostní navigace
E-application
Search Search Close
Publication detail
DREXLER, P. FIALA, P. STEINBAUER, M.
Original Title
IDENTIFYING OF THE SPECIAL PURPOSE GENERATOR PULSES
Type
conference paper
Language
English
Original Abstract
There are some suitable methods for the measurement of ultra-short solitary electromagnetic pulses (EMP) that are generated by high power microwave generators. The characteristics of EMPs are high power level and very short time duration. Special requirements for measurement methodsn have to be considered because of the specific EMPs properties. In the paper, two suitable methods for this application are presented. The first one, the calorimetric method, utilizes the thermal impacts of microwave absorption. The second method presented the magneto-optic method - uses the Faradays magneto-optic effect as a sensor principle. A combined calorimetric sensor was realized and there were made some experimental EMP measurements with good results. The sensor utilizing the magneto-optic method is still in development.
Keywords
ultra-short solitary electromagnetic pulses, calorimetric sensor
Authors
DREXLER, P.; FIALA, P.; STEINBAUER, M.
RIV year
2007
Released
1. 7. 2007
Publisher
UTEE, FEKT VUT v Brně
Location
Paris
ISBN
978-80-214-3476-9
Book
TIEF 2007
Pages from
1
Pages to
6
Pages count
BibTex