P.Špičák, V. Svoboda, M. Sedlaříková, J. Vondrák, J. Kazelle
Original Title
Elektrodes for elektrochromic devices studied by QCM
Type
conference paper
Language
English
Original Abstract
The mass of thin layer electrodes can be observed by the QCB method it is based on the changes of resonance frequency of a quartz crystal resonator. The investigated substance is deposited on the surface of the resonator. Various metals Pt, Au, Ag and their compounds should be plated on the resonator. Most frequently, the resonators for the frequency 5,0 MHz are used.The crystal surface with the layer is exposed to the electrolyte in a three electrode system, usually driven by a potentiostat. This frequency change is used for detection of chemical changes of the electrode surface. This system is very sensitive.
Keywords
Quartz crystal balance
Authors
RIV year
2006
Released
30. 4. 2006
Location
Brno
ISBN
80-214-3181-4
Book
7 th ABA BRNO 2006 Advanced Batteries and Accumulators
Pages from
165
Pages to
167
Pages count
3
BibTex
@inproceedings{BUT24360, author="Vít {Svoboda} and Petr {Špičák} and Marie {Sedlaříková} and Jiří {Vondrák} and Jiří {Kazelle}", title="Elektrodes for elektrochromic devices studied by QCM", booktitle="7 th ABA BRNO 2006 Advanced Batteries and Accumulators", year="2006", volume="7", pages="3", address="Brno", isbn="80-214-3181-4" }