Original Abstract
The article provides a brief description of measurement methods which are suitable for measurement of parameters of the high power electromagnetic pulses. Special requirements for measurement methods have to be considered because of the specific properties of EMPs and the parameters of output quantities of pulsed power sources. For measurement of current pulse which is generated in pulsed power source the magnetooptical method was proposed. This method was experimentally realized in collinear configuration. The properties of the EMP which is generated by the high power microwave source can be quantified by means of calorimetric method. On the basis of this method, the calorimetric sensor was constructed and utilized for experimental measurement.
Keywords
optical measurement methods, EMP, magnetooptic effect, electrooptic effect
Authors
FIALA, P.; DREXLER, P.; STEINBAUER, M.
RIV year
2008
Released
24. 3. 2008
Publisher
The Electromagnetic academy
Location
Cambridge
ISBN
978-1-934142-00-4
Book
PIERS 2008 Hangzhou
1559-9450
Periodical
Progress In Electromagnetics
State
United States of America
Pages from
1006
Pages to
1010
Pages count
5
BibTex
@inproceedings{BUT25992, author="Pavel {Fiala} and Petr {Drexler} and Miloslav {Steinbauer}", title="Optical Methods Identifying of the Special Purpose Generator Pulses", booktitle="PIERS 2008 Hangzhou", year="2008", journal="Progress In Electromagnetics", pages="1006--1010", publisher="The Electromagnetic academy", address="Cambridge", isbn="978-1-934142-00-4", issn="1559-9450" }