Original Abstract
This article focuses on lightweight structural concrete's (LC 35/38) resistance. To evaluate the frost resistance were simultaneously used two methods. The first procedure is based on determination of frost resistance coefficient. A bending tensile strength and a compressive strength have to be tested to achieve data for calculation of the mentioned coefficient. The second process uses non-destructive testing methods (ultrasonic impulse method and resonance method) to observe internal structural damage.
Keywords
Lightweight concrete, freeze-thaw resistance, ultrasonic impulse method, resonance method, three-point bending test
Authors
HLAVÁČ, Z.; KUCHARCZYKOVÁ, B.; CIKRLE, P.
RIV year
2008
Released
12. 11. 2008