Přístupnostní navigace
E-application
Search Search Close
Publication detail
PÍŠKA, M.
Original Title
Rigid olecranon fixation: A comparison of two techniques
Type
journal article - other
Language
English
Original Abstract
A new fixation with threaded Medin K wires has been compared with standard AO technique for a two twist techniques. Thawed fresh frozen human elbow joints were used for this study. The gap distraction increased when a moment was applied and almost returned to its previous state when the moment was removed due to visco-elastic behaviour of the ligament. Early gap opening seems to be a featur of the TBW when loaded. The new technique of two partially threaded K wires may compete with the fixation of the two twist TBW under these clinical conditions.
Keywords
oleocranon, fixation, K-wire
Authors
RIV year
2004
Released
1. 11. 1998
Publisher
BORS Oxford
Location
Oxford
ISBN
0310-620X
Periodical
Journal of Bone and Joint Surgery (Br)
Year of study
1998
Number
80(B)
State
United Kingdom of Great Britain and Northern Ireland
Pages from
258
Pages to
Pages count
1
BibTex
@article{BUT41181, author="Miroslav {Píška}", title="Rigid olecranon fixation: A comparison of two techniques", journal="Journal of Bone and Joint Surgery (Br)", year="1998", volume="1998", number="80(B)", pages="258--258", issn="0310-620X" }