Přístupnostní navigace
E-application
Search Search Close
Publication detail
ŠTĚPÁNEK, P. ŠVAŘÍČKOVÁ, I. VAŇURA, T. ADÁMEK, J.
Original Title
Long-term Test Arrangement for Externally Strengthened Reinfoced Concrete Elements
Type
journal article - other
Language
English
Original Abstract
Methods for external strengthening of concrete use elements of very high tensional strength glued onto its tensioned surface. These elements may be of metal, carbon fibres (CFRP), glass or others, usually having very good mechanical properties. However, these high-strength elements aare normally attached to concrete by exposy resins. Exposy resins have a low Young s modulus and therefore a higher rate of creep may have an influence on the long-term behaviour of such external strengthening. In order to verify this idea experimentally a special space-saving arrangement of tests is describe in this paper. Panels act as loaded beams but simultaneously as a load for the other panels in a stand. The different load magnitude acting on a different layer of panels should make it possible to study the long-term influence of the degree of shear force on the glue creep. Certainly, the glue creep may be dependent on the type of epoxy resin; therefore several epoxy resin types are included in the tests. anotace: (anglicky) Methods for external strengthening of concrete use elements of very high tensional strength glued onto its tensioned surface. These elements may be of metal, carbon fibres (CFRP), glass or others, usually having very good mechanical properties. However, these high-strength elements aare normally attached to concrete by exposy resins. Exposy resins have a low Young s modulus and therefore a higher rate of creep may have an influence on the long-term behaviour of such external strengthening. In order to verify this idea experimentally a special space-saving arrangement of tests is describe in this paper. Panels act as loaded beams but simultaneously as a load for the other panels in a stand. The different load magnitude acting on a different layer of panels should make it possible to study the long-term influence of the degree of shear force on the glue creep. Certainly, the glue creep may be dependent on the type of epoxy resin; therefore several epoxy resin types are included in the tests.
Keywords
Methods for external strengthening of concrete, carbon fibres, mechanical properties, Young s modul, long-term behaviour
Authors
ŠTĚPÁNEK, P.; ŠVAŘÍČKOVÁ, I.; VAŇURA, T.; ADÁMEK, J.
RIV year
2003
Released
1. 11. 2003
Publisher
The Czech Technical University in Prague
Location
Praha
ISBN
1210-2709
Periodical
Acta Polytechnica
Year of study
Number
4
State
Czech Republic
Pages from
27-29
Pages count
3