Přístupnostní navigace
E-application
Search Search Close
Publication detail
FIALA, P. DREXLER, P.
Original Title
Sensors and Methods for Electromagnetic Pulse Identification
Type
journal article - other
Language
English
Original Abstract
There are some suitable methods for the measurement of ultra-short solitary electromagnetic pulses that can be generated by high power pulsed generators. The measurement methods properties have to correspond to the fact whether we want to measure pulses of voltage, current or free-space electromagnetic wave. The need for specific measurement methods occurred by the development of high power microwave pulse generator [1]. Applicable methods are presented in this paper. The method utilizing Faraday's induction law allows the measurement of generated current. For the same purpose the magneto-optic method can be utilized, with its advantages. For measurement of output microwave pulse of the generator the calorimetric method was designed and realized.
Keywords
Electromagnetic pulse, High power microwave generator, Calorimetric method, Magneto-optical effect, Vircator
Authors
FIALA, P.; DREXLER, P.
RIV year
2006
Released
1. 1. 2006
ISBN
1726-5479
Periodical
Sensors & Transducers
Year of study
74
Number
12
State
Canada
Pages from
844
Pages to
854
Pages count
11
BibTex
@article{BUT43807, author="Pavel {Fiala} and Petr {Drexler}", title="Sensors and Methods for Electromagnetic Pulse Identification", journal="Sensors & Transducers", year="2006", volume="74", number="12", pages="844--854", issn="1726-5479" }