Publication detail

Measurement of pyroelectric sensor signal using low-noise wideband measurement preamplifier

KNÁPEK, A. HUTAŘ, O.

Original Title

Measurement of pyroelectric sensor signal using low-noise wideband measurement preamplifier

Type

journal article - other

Language

English

Original Abstract

In this paper, a theoretical approach of a wideband preamplifier using a high-end operation amplifier OPA847 will be presented. This device is designed tobe used for a low noise, wide band measuring. The level of optimization is based on a noise model for the electrical part of the receiver. During the process of amplifier designing, all the noise components have been investigated separately, using operational amplifiers models. Although this preamplifier was designed to serve for the purposes of flame sensors evaluate, it can be also used to other purposes requiring wide band amplifier with low noise, under only a minimal modification.

Keywords

pyroelectric sensor, noise measurements, flame detectors

Authors

KNÁPEK, A.; HUTAŘ, O.

RIV year

2008

Released

1. 11. 2008

Publisher

Jemná Mechanika a Optika

Location

Přerov

ISBN

0447-6441

Periodical

Jemná mechanika a optika

Year of study

53

Number

10

State

Czech Republic

Pages from

276

Pages to

278

Pages count

3

BibTex

@article{BUT47993,
  author="Alexandr {Knápek} and Otakar {Hutař}",
  title="Measurement of pyroelectric sensor signal using low-noise wideband measurement preamplifier",
  journal="Jemná mechanika a optika",
  year="2008",
  volume="53",
  number="10",
  pages="276--278",
  issn="0447-6441"
}