Publication detail

Experimental methods for simultaneous measurement of action potentials and electrograms in isolated heart

KOLÁŘOVÁ, J. FIALOVÁ, K. JANOUŠEK, O. NOVÁKOVÁ, M. PROVAZNÍK, I.

Original Title

Experimental methods for simultaneous measurement of action potentials and electrograms in isolated heart

Type

journal article in Web of Science

Language

English

Original Abstract

Monophasic action potential (MAP) can be recorded from the heart surface by optical method based on fluorescence measurement. The motion of isolated heart during experiment caused additional noise in recorded signal. The motion artifact can be eliminated by ratiometric fluorescence emission measurements. This study is based on experiments in which optical MAP measurement is done by single-wavelength and dual-wavelength measurement of fluorescence emission. Both recording setups are presented and their advantages and disadvantages are discussed. MAPs recorded by both methods from isolated rabbit hearts perfused according to Langendorff are presented. Simultaneous electrograms (EG) and MAPs recording are analyzed and measurement of velocity of impulse conduction through heart tissue is presented.

Keywords

isolated heart, action potential, electrogram, voltage sensitive dye, ratiometry

Authors

KOLÁŘOVÁ, J.; FIALOVÁ, K.; JANOUŠEK, O.; NOVÁKOVÁ, M.; PROVAZNÍK, I.

RIV year

2010

Released

28. 5. 2010

Publisher

AV ČR

Location

Praha

ISBN

0862-8408

Periodical

Physiological Research

Year of study

59

Number

Suppl 1

State

Czech Republic

Pages from

S71

Pages to

S80

Pages count

10