Přístupnostní navigace
E-application
Search Search Close
Publication detail
STOJAN, R. VANĚK, J. DOLENSKÝ, J.
Original Title
Control system for very low temperature during the defection detection of solar cells
Type
journal article - other
Language
English
Original Abstract
This work deals with measuring of very low temperatures during the detection of local solar cells defects by luminescence method. Temperature in cryo area is measured by the thermocouples. Liquid nitrogen is used to cooling the solar cells. A main part of this work is concept and making equipment for temperature controlling in cryo technique. This equipment is also signaling danger of frost-bite scorch in low temperatures.
Keywords
temperature measurement, liquid nitrogen, thermocouples
Authors
STOJAN, R.; VANĚK, J.; DOLENSKÝ, J.
RIV year
2010
Released
22. 9. 2010
Publisher
Faculty of Electronic Enegineering nad Technologies, Technical University of Sofia
Location
Sofia, Bulgaria
ISBN
1313-1842
Periodical
Electronics
Year of study
Number
4
State
Republic of Bulgaria
Pages from
16
Pages to
18
Pages count
3
BibTex
@article{BUT50782, author="Radek {Stojan} and Jiří {Vaněk} and Jan {Dolenský}", title="Control system for very low temperature during the defection detection of solar cells", journal="Electronics", year="2010", volume="2010", number="4", pages="16--18", issn="1313-1842" }