ADÁMEK, J. STEHLÍK, M. CIKRLE, P.
Original Title
Correlation between data double flat-jack test and sonic velocities
Type
report
Language
English
Original Abstract
Double flat jack method is used for moduli of elasticity determination. Time of ultrasound wave propagation is also the base for modulus of elasticity determination. Comparison of results of both methods gives you correlatin equation for further use.
Keywords
double flat jacks, modulus of elasticity, ultrasound, dynamic modulus of elasticity
Authors
ADÁMEK, J.; STEHLÍK, M.; CIKRLE, P.
Released
15. 1. 2004
Publisher
ÚTAM Praha
Location
Praha
Pages from
32
Pages to
87
Pages count
55