CASTILLO, G. TRNKOVÁ, L. HRDÝ, R. HIANIK, T.
Original Title
Impedimetric Aptasensor for Thrombin Recognition Based on CD Support
Type
journal article in Web of Science
Language
English
Original Abstract
We report an aptamer biosensing array for thrombin detection by measuring the electrochemical impedance upon aptamer-protein formation at the surface of CD-trodes (GCDTs) in the presence of the redox couple [Fe(CN)6]3/4. GCDTs are fabricated from recordable compact discs that contain a fine gold layer. The biosensor is constructed by self-assembling of a thiol-modified thrombin binding aptamer (TBA) onto a GCDT surface. The sensor reveals good ligand specificity, recognition in a wide range of thrombin concentrations from 20 nM to 1 mM with a limit of detection of 5 nM
Keywords
DNA aptamers, Biosensors, Human thrombin, Electrochemical impedance spectroscopy
Authors
CASTILLO, G.; TRNKOVÁ, L.; HRDÝ, R.; HIANIK, T.
RIV year
2012
Released
1. 5. 2012
ISBN
1040-0397
Periodical
ELECTROANALYSIS
Year of study
24
Number
5
State
Federal Republic of Germany
Pages from
1079
Pages to
1087
Pages count
9
BibTex
@article{BUT92982, author="Gabriela {Castillo} and Libuše {Trnková} and Radim {Hrdý} and Tibor {Hianik}", title="Impedimetric Aptasensor for Thrombin Recognition Based on CD Support", journal="ELECTROANALYSIS", year="2012", volume="24", number="5", pages="1079--1087", doi="10.1002/elan.201200041", issn="1040-0397" }