Přístupnostní navigace
E-application
Search Search Close
Publication detail
ŠTĚPÁNKOVÁ, E. DZIK, P. FÜRST, T. VESELÝ, M.
Original Title
Determining The Light-Fastness Of Photographic Output Media Using Gamut Volume
Type
abstract
Language
English
Original Abstract
In this work, samples produced by chromogenic and special photographic processes as well as inkjet printing techniques were studied in a long-term and accelerated lightfastnesstest.Colour changes of the samples were followed spectrophotometricallyduring both tests. Gamut volumes were calculatedfrom the measured spectra using a custom-programmed utility calledVolGa. Gamut volume change was used as a measure ofsample degradation and was plotted against the corresponding exposure dose. From the regression analysis of the recorded gamut shrinkage data, formal parameters of the fadingrate were determined which can also serve as a tool for the expression of predicted lifetimes. Sample comparison was performed on the basis of 30% gamut volume loss as the suggested endpoint criterion.
Keywords
VolGa, colour gamut, lifetime evaluation
Authors
ŠTĚPÁNKOVÁ, E.; DZIK, P.; FÜRST, T.; VESELÝ, M.
Released
2. 7. 2012
BibTex
@misc{BUT94014, author="Eva {Štěpánková} and Petr {Dzik} and Tomáš {Fürst} and Michal {Veselý}", title="Determining The Light-Fastness Of Photographic Output Media Using Gamut Volume", year="2012", note="abstract" }