BENÁČKOVÁ, J. FRÝBA, L. PAVLAS, M. FERDAN, T.
Original Title
DETERMINATION OF BOILER EFFICIENCY AND LOWER HEATING VALUE OF MUNICIPAL SOLID WASTE AT REAL WASTE-TO-ENERGY PLANT
Type
conference paper
Language
English
Original Abstract
The Lower heating value (LHV) is the key parameter influencing economy. The LHV of municipal solid waste (LHVW) is computed by processing set of operational data from a real waste-to-energy plant recommended by the Reference document on the Best Available Techniques for Waste Incineration (BREF/BAT). It is necessary to determine the LHVW for calculation of combustion chamber efficiency. The efficiency was calculated by three different methods: the direct, the indirect and the "modified" indirect method. Each method is variously sensitive to an input parameters measurement error. It can eliminate the error in measurement or input parameters.
Keywords
boiler efficiency, heating value, Waste to Energy Plant
Authors
BENÁČKOVÁ, J.; FRÝBA, L.; PAVLAS, M.; FERDAN, T.
RIV year
2013
Released
2. 1. 2013
Location
Hradec Králové, The Czech Republic
ISBN
978-80-905243-3-0
Book
Mezinárodní Masarykova konference pro doktorandy a mladé vědecké pracovníky 2012
Edition number
III
Pages from
3072
Pages to
3081
Pages count
10
BibTex
@inproceedings{BUT96351, author="Jana {Benáčková} and Lukáš {Frýba} and Martin {Pavlas} and Tomáš {Ferdan}", title="DETERMINATION OF BOILER EFFICIENCY AND LOWER HEATING VALUE OF MUNICIPAL SOLID WASTE AT REAL WASTE-TO-ENERGY PLANT", booktitle="Mezinárodní Masarykova konference pro doktorandy a mladé vědecké pracovníky 2012", year="2013", number="III", pages="3072--3081", address="Hradec Králové, The Czech Republic", isbn="978-80-905243-3-0" }