Original Abstract

The Lower heating value (LHV) is the key parameter influencing economy. The LHV of municipal solid waste (LHVW) is computed by processing set of operational data from a real waste-to-energy plant recommended by the Reference document on the Best Available Techniques for Waste Incineration (BREF/BAT). It is necessary to determine the LHVW for calculation of combustion chamber efficiency. The efficiency was calculated by three different methods: the direct, the indirect and the "modified" indirect method. Each method is variously sensitive to an input parameters measurement error. It can eliminate the error in measurement or input parameters.

Keywords

boiler efficiency, heating value, Waste to Energy Plant

Authors

BENÁČKOVÁ, J.; FRÝBA, L.; PAVLAS, M.; FERDAN, T.

RIV year

2013

Released

2. 1. 2013

Location

Hradec Králové, The Czech Republic

ISBN

978-80-905243-3-0

Book

Mezinárodní Masarykova konference pro doktorandy a mladé vědecké pracovníky 2012

Edition number

III

Pages from

3072

Pages to

3081

Pages count

10

BibTex

@inproceedings{BUT96351,
  author="Jana {Benáčková} and Lukáš {Frýba} and Martin {Pavlas} and Tomáš {Ferdan}",
  title="DETERMINATION OF BOILER EFFICIENCY AND LOWER HEATING VALUE OF MUNICIPAL SOLID WASTE AT REAL WASTE-TO-ENERGY PLANT",
  booktitle="Mezinárodní Masarykova konference pro doktorandy a mladé vědecké pracovníky 2012",
  year="2013",
  number="III",
  pages="3072--3081",
  address="Hradec Králové, The Czech Republic",
  isbn="978-80-905243-3-0"
}