Přístupnostní navigace
E-application
Search Search Close
Publication detail
ŠPANĚL, P.
Original Title
The leakage inductance dependence on HF transformer winding arrangement
Type
conference paper
Language
English
Original Abstract
The series resonant converter often uses the leakage inductance of transformers as resonant inductance in series with resonance capacitor. So the resonant capacitor is used to compensate the leakage inductance on set switching frequency. The leakage inductance of transformer can be affected in wide range, just by different arrangement of transformer windings around the core. It means that in the most cases the additional inductor neednt to be used.
Keywords
resonant converter, leakage inductance, series resonant converter, transformer
Key words in English
Authors
RIV year
2013
Released
25. 4. 2013
Publisher
LITERA
ISBN
978-80-214-4695-3
Book
Student EEICT Proceedings of the 19th conference Volume 3
Pages from
123
Pages to
127
Pages count
4
BibTex
@inproceedings{BUT99518, author="Petr {Španěl}", title="The leakage inductance dependence on HF transformer winding arrangement", booktitle="Student EEICT Proceedings of the 19th conference Volume 3", year="2013", pages="123--127", publisher="LITERA", isbn="978-80-214-4695-3" }