Publication detail

Transfer Function of Power Line Channel – Influence of Topology Parameters and Power Line Topology Estimation

MLÝNEK, P. MIŠUREC, J. KOUTNÝ, M. FUJDIAK, R.

Original Title

Transfer Function of Power Line Channel – Influence of Topology Parameters and Power Line Topology Estimation

Type

conference paper

Language

English

Original Abstract

The article presents an analysis of the influence of power line characteristic and power line topology parameters on transfer function. The effects of load impedance, branch length, number of branches, and time and frequency selectivity of terminal impedance are shown in this analysis. The analysis results give power line network parameters which have a significant effect on the transfer function and attenuation. Based on this analysis, a method for managing the power line topology is proposed.

Keywords

Power distribution lines, transfer function, topology

Authors

MLÝNEK, P.; MIŠUREC, J.; KOUTNÝ, M.; FUJDIAK, R.

RIV year

2014

Released

13. 10. 2014

ISBN

9781479936540

Book

The 5th IEEE PES Innovative Smart Grid Technologies (ISGT) European 2014 Conference

Pages from

1

Pages to

5

Pages count

5

BibTex

@inproceedings{BUT110250,
  author="Petr {Mlýnek} and Jiří {Mišurec} and Martin {Koutný} and Radek {Fujdiak}",
  title="Transfer Function of Power Line Channel – Influence of Topology Parameters and Power Line Topology Estimation",
  booktitle="The 5th IEEE PES Innovative Smart Grid Technologies (ISGT) European 2014 Conference",
  year="2014",
  pages="1--5",
  isbn="9781479936540"
}