PAŘÍLKOVÁ, J. ZACHOVAL, Z. PAŘÍLEK, L. FRÁNKOVÁ, H. PAZDÍREK, O.
Original Title
The measurement of the water level in the Hornice reservoir
Type
conference paper
Language
English
Original Abstract
The knowledge of the water level in a reservoir can be required not only because of its best use, but also from the point of view of its safe operation. An inrush of water has been observed on the downstream face of the earth-fill embankment dam of the Hornice reservoir; it can be a result of its hydrodynamic stress, e.g. during floods, i.e. the fluctuation of the water level in the reservoir. This paper presents the issue of measurement of the water level in the reservoir and the method of electrical impedance spectrometry used for its measurement.
Keywords
earth-fill dam, movement of water level, electrical impedance spectrometry
Authors
PAŘÍLKOVÁ, J.; ZACHOVAL, Z.; PAŘÍLEK, L.; FRÁNKOVÁ, H.; PAZDÍREK, O.
Released
13. 10. 2016
Publisher
Brno University of Technology, VUTIUM
Location
Brno
ISBN
978-80-214-5338-8
Book
EUREKA 2016 - 4th conference and working session
Edition
neuv
Edition number
1
2464-4595
Periodical
EUREKA
Year of study
Number
State
Czech Republic
Pages from
219
Pages to
242
Pages count
24
BibTex
@inproceedings{BUT131951, author="Jana {Pařílková} and Zbyněk {Zachoval} and Luboš {Pařílek} and Hana {Fránková} and Otakar {Pazdírek}", title="The measurement of the water level in the Hornice reservoir", booktitle="EUREKA 2016 - 4th conference and working session", year="2016", series="neuv", journal="EUREKA", volume="1", number="1", pages="219--242", publisher="Brno University of Technology, VUTIUM", address="Brno", isbn="978-80-214-5338-8", issn="2464-4595" }