Publication detail

Design and testing of magnetorheological valve with fast force response time and great dynamic force range

KUBÍK, M. MACHÁČEK, O. ROUPEC, J. STRECKER, Z. MAZŮREK, I.

Original Title

Design and testing of magnetorheological valve with fast force response time and great dynamic force range

Type

journal article in Web of Science

Language

English

Original Abstract

The paper deals with design, simulation and experimental testing of a magnetorheological (MR) valve with short response time. The short response time is achieved by a suitable design of an active zone in combination with use of a ferrite material for magnetic circuit. The magneto-static model and the simplified hydraulic model of the MR valve are examined and experimentally verified. The development the MR valve achieves an average response time 4.1 ms and the maximum dynamic force range of eight.

Keywords

MR fluid, magnetorheological fluid, MR damper, magnetorheological damper

Authors

KUBÍK, M.; MACHÁČEK, O.; ROUPEC, J.; STRECKER, Z.; MAZŮREK, I.

Released

7. 3. 2017

ISBN

0964-1726

Periodical

SMART MATERIALS & STRUCTURES

Year of study

26

Number

4

State

United Kingdom of Great Britain and Northern Ireland

Pages from

1

Pages to

10

Pages count

10

URL

BibTex

@article{BUT134153,
  author="Michal {Kubík} and Ondřej {Macháček} and Jakub {Roupec} and Zbyněk {Strecker} and Ivan {Mazůrek}",
  title="Design and testing of magnetorheological valve with fast force response time and great dynamic force range",
  journal="SMART MATERIALS & STRUCTURES",
  year="2017",
  volume="26",
  number="4",
  pages="1--10",
  doi="10.1088/1361-665X/aa6066",
  issn="0964-1726",
  url="http://iopscience.iop.org/article/10.1088/1361-665X/aa6066/pdf"
}