Publication detail

Design of the conic static probe tip of the Pitot’s tube in experimental chamber.

HLAVATÁ, P. MAXA, J. VYROUBAL, P.

Original Title

Design of the conic static probe tip of the Pitot’s tube in experimental chamber.

Type

conference paper

Language

English

Original Abstract

This article comes out from the series of articles devoted to the issue of pumping in the differentially pumped chamber. This article is based on a study of Dr. Danilatos, where pumping of the differential pumped chamber is solved using the Monte Carlo statistical method. To solve the problem we use the mechanics of continuum with experimental verification. The article deals with a construction of the conic tip of the static probe.

Keywords

Ansys, Differentially Pumped Chamber, Taylor Maccoll Analysis, Pitot’s tube

Authors

HLAVATÁ, P.; MAXA, J.; VYROUBAL, P.

Released

27. 8. 2018

Publisher

Brno University of Technology

Location

Brno

ISBN

978-80-214-5651-8

Book

Advanced Batteries Accumulators and Fuel Cells – 19th ABAF

Pages from

58

Pages to

61

Pages count

4

BibTex

@inproceedings{BUT150605,
  author="Pavla {Šabacká} and Jiří {Maxa} and Petr {Vyroubal}",
  title="Design of the conic static probe tip of the Pitot’s tube in experimental chamber.",
  booktitle="Advanced Batteries Accumulators and Fuel Cells – 19th ABAF",
  year="2018",
  pages="58--61",
  publisher="Brno University of Technology",
  address="Brno",
  isbn="978-80-214-5651-8"
}