Přístupnostní navigace
E-application
Search Search Close
Publication detail
ŠABACKÁ, P. MAXA, J. VYROUBAL, P.
Original Title
Comparative analysis of inserted temperature probe in the differentially pumped
Type
conference paper
Language
English
Original Abstract
This article deals with the experimental chamber preparation, on which stagnation and static temperature (besides others) will be measured. The results obtained from measurement will be compared with the results from mathematical – physics analysis of Ansys Fluent system and in this system, the temperature running and expected ratios for planned experimental measuring also will be mapped in the supersonic flow in the experimental chambers.
Keywords
Ansys, probe, Differentialy pumped
Authors
ŠABACKÁ, P.; MAXA, J.; VYROUBAL, P.
Released
8. 9. 2019
Publisher
Brno University of Technology
Location
Brno
ISBN
978-80-214-5774-4
Book
Advanced Batteries Accumulators and Fuel Cells – 20th ABAF
Edition
1
Edition number
Pages from
183
Pages to
186
Pages count
4
URL
https://aba-brno.cz/download/2019-ABAF-Proceeding.pdf
BibTex
@inproceedings{BUT159305, author="Pavla {Šabacká} and Jiří {Maxa} and Petr {Vyroubal}", title="Comparative analysis of inserted temperature probe in the differentially pumped", booktitle="Advanced Batteries Accumulators and Fuel Cells – 20th ABAF", year="2019", series="1", number="1", pages="183--186", publisher="Brno University of Technology", address="Brno", isbn="978-80-214-5774-4", url="https://aba-brno.cz/download/2019-ABAF-Proceeding.pdf" }