PETROSYAN, T. SUK, L. KATOVSKÝ, K.
Original Title
Analysis of passive heat removal system through steam generator by ANSYS fluent
Type
conference paper
Language
English
Original Abstract
This paper presents the simulation of the condensation of water vapor in one tube of heat exchanger in Passive Heat Removal System, which is a protective safety system of the Nuclear Power Plant. The simulation accounts for the two-phase turbulent flow of the water vapor along the tube with an assumption of constant wall temperature. The results from the CFD (Computational Fluid Dynamics) simulations are compared with the experimental results from the literature for the condensation of water vapor for inlet velocities of 1 m/s and 3 m/s, as well as with the result of simulation analyzed by other software.
Keywords
Condensation; Steam Generator; ANSYS; Passive Heat Removal; Nuclear Safety
Authors
PETROSYAN, T.; SUK, L.; KATOVSKÝ, K.
Released
22. 10. 2019
Publisher
American Institute of Physics Inc.
Location
AIP College Park Maryland, USA
ISBN
978-0-7354-1908-7
Book
AIP Conference Proceedings, Volume 2163, 23rd International Scientific Conference of Young Scientists and Specialists, AYSS 2019
0094-243X
Periodical
AIP conference proceedings
Year of study
2163
Number
060002
State
United States of America
Pages from
060002-1
Pages to
060002-5
Pages count
5