Publication detail

Analysis of passive heat removal system through steam generator by ANSYS fluent

PETROSYAN, T. SUK, L. KATOVSKÝ, K.

Original Title

Analysis of passive heat removal system through steam generator by ANSYS fluent

Type

conference paper

Language

English

Original Abstract

This paper presents the simulation of the condensation of water vapor in one tube of heat exchanger in Passive Heat Removal System, which is a protective safety system of the Nuclear Power Plant. The simulation accounts for the two-phase turbulent flow of the water vapor along the tube with an assumption of constant wall temperature. The results from the CFD (Computational Fluid Dynamics) simulations are compared with the experimental results from the literature for the condensation of water vapor for inlet velocities of 1 m/s and 3 m/s, as well as with the result of simulation analyzed by other software.

Keywords

Condensation; Steam Generator; ANSYS; Passive Heat Removal; Nuclear Safety

Authors

PETROSYAN, T.; SUK, L.; KATOVSKÝ, K.

Released

22. 10. 2019

Publisher

American Institute of Physics Inc.

Location

AIP College Park Maryland, USA

ISBN

978-0-7354-1908-7

Book

AIP Conference Proceedings, Volume 2163, 23rd International Scientific Conference of Young Scientists and Specialists, AYSS 2019

ISBN

0094-243X

Periodical

AIP conference proceedings

Year of study

2163

Number

060002

State

United States of America

Pages from

060002-1

Pages to

060002-5

Pages count

5