Přístupnostní navigace
E-application
Search Search Close
Publication detail
VITOUŠ, J. JIŘÍK, R. STRAČINA, T. HENDRYCH, M. NÁDENÍČEK, J. MACÍČEK, O. TIAN, Y. KRÁTKÁ, L. DRAŽANOVÁ, E. NOVÁKOVÁ, M. BABULA, P. PANOVSKÝ, R. DIBELLA, E. STARČUK, Z.
Original Title
T1 mapping of myocardium in rats using self-gated golden-angle acquisition
Type
journal article in Web of Science
Language
English
Original Abstract
PurposeThe aim of this study is to design a method of myocardial T1 quantification in small laboratory animals and to investigate the effects of spatiotemporal regularization and the needed acquisition duration.MethodsWe propose a compressed-sensing approach to T1 quantification based on self-gated inversion-recovery radial two/three-dimensional (2D/3D) golden-angle stack-of-stars acquisition with image reconstruction performed using total-variation spatiotemporal regularization. The method was tested on a phantom and on a healthy rat, as well as on rats in a small myocardium-remodeling study.ResultsThe results showed a good match of the T1 estimates with the results obtained using the ground-truth method on a phantom and with the literature values for rats myocardium. The proposed 2D and 3D methods showed significant differences between normal and remodeling myocardium groups for acquisition lengths down to approximately 5 and 15 min, respectively.ConclusionsA new 2D and 3D method for quantification of myocardial T1 in rats was proposed. We have shown the capability of both techniques to distinguish between normal and remodeling myocardial tissue. We have shown the effects of image-reconstruction regularization weights and acquisition length on the T1 estimates.
Keywords
MRI, retrospective gating, cardiac, fibrosis, remodeling, T1, quantification
Authors
VITOUŠ, J.; JIŘÍK, R.; STRAČINA, T.; HENDRYCH, M.; NÁDENÍČEK, J.; MACÍČEK, O.; TIAN, Y.; KRÁTKÁ, L.; DRAŽANOVÁ, E.; NOVÁKOVÁ, M.; BABULA, P.; PANOVSKÝ, R.; DIBELLA, E.; STARČUK, Z.
Released
9. 10. 2023
Publisher
John Wiley and Sons
ISBN
0740-3194
Periodical
MAGNETIC RESONANCE IN MEDICINE
Year of study
91
Number
1
State
United States of America
Pages from
368
Pages to
380
Pages count
13
URL
https://onlinelibrary.wiley.com/doi/10.1002/mrm.29846
Full text in the Digital Library
http://hdl.handle.net/11012/244166
BibTex
@article{BUT184699, author="Jiří {Vitouš} and Radovan {Jiřík} and Tibor {Stračina} and Michal {Hendrych} and Jaroslav {Nádeníček} and Ondřej {Macíček} and Ye {Tian} and Lucie {Krátká} and Eva {Dražanová} and Marie {Nováková} and Petr {Babula} and Roman {Panovský} and Edward {DiBella} and Zenon {Starčuk}", title="T1 mapping of myocardium in rats using self-gated golden-angle acquisition", journal="MAGNETIC RESONANCE IN MEDICINE", year="2023", volume="91", number="1", pages="368--380", doi="10.1002/mrm.29846", issn="0740-3194", url="https://onlinelibrary.wiley.com/doi/10.1002/mrm.29846" }