Publication detail

Accuracy Measurement of Air Ion Concentration

BARTUŠEK, K. FIALA, P. BACHOREC, T. STEINBAUER, M.

Original Title

Accuracy Measurement of Air Ion Concentration

Type

conference paper

Language

English

Original Abstract

An analysis of the electric state of air shows the presence of various ion sorts. The therapeutic effect of negative high-mobility ions of proper concentration is known. This positive effect was observed in caves that are used for speleotherapy. This article presents the capability of methods for measuring ion concentration and for ion spectral analysis.

Keywords

ion concentration, ion spectral analysis

Authors

BARTUŠEK, K.; FIALA, P.; BACHOREC, T.; STEINBAUER, M.

RIV year

2007

Released

20. 9. 2007

Publisher

Ing. Zdeněk Novotný, CSc., Brno, Ondráčkova 105

Location

Vysoké učení technické v Brně, Antonínská 548/1

ISBN

978-80-214-3470-7

Book

Electronic Devices and Systems EDS '07 IMAPS CS International Conference 2007

Edition number

první

Pages from

173

Pages to

177

Pages count

5

BibTex

@inproceedings{BUT23040,
  author="Karel {Bartušek} and Pavel {Fiala} and Tibor {Bachorec} and Miloslav {Steinbauer}",
  title="Accuracy Measurement of Air Ion Concentration",
  booktitle="Electronic Devices and Systems EDS '07 IMAPS CS International Conference 2007",
  year="2007",
  number="první",
  pages="173--177",
  publisher="Ing. Zdeněk Novotný, CSc., Brno, Ondráčkova 105",
  address="Vysoké učení technické v Brně, Antonínská 548/1",
  isbn="978-80-214-3470-7"
}