Přístupnostní navigace
E-application
Search Search Close
Publication detail
HUZLÍK, R.
Original Title
COMPARISON OF PMSM AND INDUCTION MACHINE BASED ON GENERALIZED SIZING EQUATION
Type
conference paper
Language
English
Original Abstract
This article is aimed to compare of induction machine and synchronous machine with per-manent magnet. This compression is based on generalized sizing equation. Comparison will be sized of machine - diameter of air gap and length. For comparison, we will suppose, that both type of machine have the same efficiency and output power. In this article there is calculated only with sizing equation and there isn't calculated with another aspect of de-sign of electrical machine.
Keywords
permenanet magnet synchronous machine, induction machine, sizing equation
Authors
RIV year
2009
Released
23. 4. 2009
Publisher
NOVPRESS s.r.o
Location
Brno
ISBN
978-80-214-3869-9
Book
Proceedings of the 15th conference Student EEICT 2009 - volume 3
Pages from
78
Pages to
81
Pages count
4
BibTex
@inproceedings{BUT33490, author="Rostislav {Huzlík}", title="COMPARISON OF PMSM AND INDUCTION MACHINE BASED ON GENERALIZED SIZING EQUATION", booktitle="Proceedings of the 15th conference Student EEICT 2009 - volume 3", year="2009", pages="78--81", publisher="NOVPRESS s.r.o", address="Brno", isbn="978-80-214-3869-9" }