Methods for High Power EM Pulse Measurement
Type
journal article - other
Language
English
Original Abstract
There are some suitable methods for the measurement of ultra-short solitary electromagnetic pulses that can be generated by high power pulsed generators. The measurement methods properties have to correspond to the fact whether we want to measure pulses of voltage, current or free-space electromagnetic wave. The need for specific measurement methods occurred by the development of high power microwave pulse generator [1]. Applicable methods are presented in this paper. The method utilizing Faraday's induction law allows the measurement of generated current. For the same purpose the magneto-optic method can be utilized, with its advantages. For measurement of output microwave pulse of the generator the calorimetric method was designed and realized.
Keywords
EMC, electromnagnetic puls, pus generator
Authors
DREXLER, P.; FIALA, P.
RIV year
2006
Released
1. 1. 2006
ISBN
1210-2512
Periodical
Radioengineering
Year of study
15
Number
4
State
Czech Republic
Pages from
43
Pages to
49
Pages count
7