Publication detail

Current distribution over the electrode surface in a lead-acid cell during discharge

KŘIVÍK, P. BAČA, P.

Original Title

Current distribution over the electrode surface in a lead-acid cell during discharge

Type

conference paper

Language

English

Original Abstract

The current distribution over the plate surface in lead-acid cells in the course of discharge was determined mathematically by using the equivalent circuit method. The dependence of the internal cell resistance on the current and charge passed was determined by measurements on a laboratory cell. Three cell variants were considered differing by the location of tabs serving as current terminals. The results are presented in the form of 3-D diagrams at various states of discharge. To make the current distribution nearly uniform, extended current tabs located at opposite ends of the plate electrodes were proposed.

Keywords

current distribution, lead-acid cells, internal cell resistance, discharge

Authors

KŘIVÍK, P.; BAČA, P.

RIV year

2002

Released

1. 5. 2002

Publisher

FEKT VUT v Brně

Location

Brno

ISBN

80-214-2082-0

Book

3rd ABA Brno 2002

Edition number

1

Pages from

11-1

Pages count

5