Original Abstract

The use of concrete with gypsum free cement (GFCC) requires resolving the issue of mix design. Gypsum free cement concrete are noted for high initial strength. After 3 days the strength of concrete can reach the value comparable with the strength of common cement after 28 days. The concrete with gypsum free cement are identified to repair works and structures which has to be in use very soon, it usually means after 1 or 3 days. Concrete mix design should concern these special properties. For mix design of GFCC is not possible use the same strength equations as for normal gypsum Portland cements, mentioned strength equations consider the 28 days strength. New strength equations for GFCC were elaborated and make possible assessment of strength after from 1 to 7 days. Mix design should also consider aggregate porosity, which sould not be more than 25%. Ideal porosity is less than 22%.

Keywords

CONCRETE, MIX DESIGN, GYPSUM FREE CEMENT

Authors

BROŽOVSKÝ, J.

RIV year

2002

Released

1. 1. 2002

Publisher

NDBIK

Location

Kyjev

ISBN

0585-4296

Periodical

Zbirnik naukovych prac NDIBK Kyjev

Year of study

2002

Number

56

State

Ukraine

Pages from

81

Pages to

88

Pages count

8