Detail publikace

Motion artefact in voltage-sensitive fluorescent dye emission during repeated ischemia of isolated heart.

JANOUŠEK, O. KOLÁŘOVÁ, J. RONZHINA, M. NOVÁKOVÁ, M. PROVAZNÍK, I.

Originální název

Motion artefact in voltage-sensitive fluorescent dye emission during repeated ischemia of isolated heart.

Typ

článek v časopise - ostatní, Jost

Jazyk

angličtina

Originální abstrakt

Motion artefact (MA) in voltage-sensitive fluorescent signals causes significant debasement of action potential. During ischemia and reperfusion in isolated rabbit heart, this artefact develops in a manner which may be described by the time of its onset, level, and shape. The MA during ischemia: (a) may become substantial with approximately two minutes delay after establishing global ischemia; (b) may be almost twice as high as the physiological action potential and decreases both with time and repetition of ischemia; (c) the MA shape is unpredictable and depends on individual rabbit.

Klíčová slova

Motion artefact, Ischemia, Isolated rabbit heart, Voltage-sensitive dye

Autoři

JANOUŠEK, O.; KOLÁŘOVÁ, J.; RONZHINA, M.; NOVÁKOVÁ, M.; PROVAZNÍK, I.

Rok RIV

2013

Vydáno

16. 4. 2013

Nakladatel

AV ČR

Místo

Praha

ISSN

0862-8408

Periodikum

Physiological Research

Ročník

62

Číslo

4

Stát

Česká republika

Strany od

371

Strany do

378

Strany počet

8

BibTex

@article{BUT101194,
  author="Oto {Janoušek} and Jana {Kolářová} and Marina {Filipenská} and Marie {Nováková} and Valentine {Provazník}",
  title="Motion artefact in voltage-sensitive fluorescent dye emission during repeated ischemia of isolated heart.",
  journal="Physiological  Research",
  year="2013",
  volume="62",
  number="4",
  pages="371--378",
  issn="0862-8408"
}