Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikace
MELICHAR, J. DROCHYTKA, R. ČERNÝ, V.
Originální název
Experimental testing of hydroinsulating injection screens
Typ
článek ve sborníku ve WoS nebo Scopus
Jazyk
angličtina
Originální abstrakt
One of the most widespread method of redevelopment of wet masonry is additional creating of hydroinsulating screen in the material. This method has many advantages. The biggest advantage is fact, that building can be repaired from inside without damaging its statics and saving it from being demolished, thus sparing the environment. In comparison to other procedures its application is quick, easy and has excellent final efficiency. Main object of this article is testing of application and total functionality of individual screens in masonry.
Klíčová slova
hydroinsulating gel screens, injection, methods of application and testing
Autoři
MELICHAR, J.; DROCHYTKA, R.; ČERNÝ, V.
Rok RIV
2014
Vydáno
16. 1. 2014
ISBN
978-3-03785-972-8
Kniha
3rd International Conference on Energy, Environment and Sustainable Development, EESD 2013
ISSN
1022-6680
Periodikum
Advanced Materials Research
Ročník
Číslo
860-863
Stát
Švýcarská konfederace
Strany od
2327
Strany do
2330
Strany počet
4
BibTex
@inproceedings{BUT103383, author="Jindřich {Melichar} and Rostislav {Drochytka} and Vít {Černý}", title="Experimental testing of hydroinsulating injection screens", booktitle="3rd International Conference on Energy, Environment and Sustainable Development, EESD 2013", year="2014", journal="Advanced Materials Research", volume="2014", number="860-863", pages="2327--2330", doi="10.4028/www.scientific.net/AMR.860-863.2327", isbn="978-3-03785-972-8", issn="1022-6680" }