MLÝNEK, P. KOUTNÝ, M. MIŠUREC, J. KOLKA, Z.
Originální název
Measurements and Evaluation of PLC Modem with G3 and PRIME Standards for Street Lighting Control
Typ
článek ve sborníku ve WoS nebo Scopus
Jazyk
angličtina
Originální abstrakt
The paper surveys narrowband power line communications (PLCs) in the context of Smart Grid and remote Street Lighting Control. The specifications G3-PLC and PRIME are discussed. The field test results and data rate measurements are presented for different scenarios. They demonstrate the problems encountered when the PLC signal is necessary to be sent through the switchgear, complicated topology, noisy topology and topology similar to simple street-light topology.
Klíčová slova
power line communication, street light, G3-PLC, PRIME, measurement
Autoři
MLÝNEK, P.; KOUTNÝ, M.; MIŠUREC, J.; KOLKA, Z.
Rok RIV
2014
Vydáno
31. 3. 2014
ISBN
978-1-4799-4961-8
Kniha
Proceeding of 2014 18th IEEE International Symposium on Power Line Communications and Its Applications
Strany od
238
Strany do
243
Strany počet
6
BibTex
@inproceedings{BUT107008, author="Petr {Mlýnek} and Martin {Koutný} and Jiří {Mišurec} and Zdeněk {Kolka}", title="Measurements and Evaluation of PLC Modem with G3 and PRIME Standards for Street Lighting Control", booktitle="Proceeding of 2014 18th IEEE International Symposium on Power Line Communications and Its Applications", year="2014", pages="238--243", isbn="978-1-4799-4961-8" }