In-situ, low dose rate, total ionising dose test of the cooling performance of a thermoelectric module
Typ
článek ve sborníku ve WoS nebo Scopus
Jazyk
angličtina
Originální abstrakt
This work presents and discusses the design and fully automated total ionising dose test of a thermoelectric cooling module. The goal was to develop a reliable test method which can be used to measure potential total ionising dose induced degradation of the cooling performance and demonstrate this method in a long term, low dose rate experiment. Details of the tested hardware and fully automated test system are published in this work, including preliminary test results and lessons learned.
Klíčová slova
automated test equipment, thermoelectric cooler, thermometers, test software, test methods, humidity measurement, humidity control
Autoři
Rok RIV
2013
Vydáno
9. 9. 2013
Nakladatel
IEEE
Místo
Oxford, UK
ISBN
9781467350556
Kniha
Procceding of RADIATION AND ITS EFFECTS ON COMPONENTS AND SYSTEMS. EUROPEAN CONFERENCE. 14TH 2013. (RADECS 2013)
Strany od
1
Strany do
4
Strany počet
BibTex
@inproceedings{BUT114104, author="Jiří {Hofman}", title="In-situ, low dose rate, total ionising dose test of the cooling performance of a thermoelectric module", booktitle="Procceding of RADIATION AND ITS EFFECTS ON COMPONENTS AND SYSTEMS. EUROPEAN CONFERENCE. 14TH 2013. (RADECS 2013)", year="2013", pages="1--4", publisher="IEEE", address="Oxford, UK", isbn="9781467350556" }