Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikace
OTAVA, L. BUCHTA, L. GRAF, M.
Originální název
Interior Permanent Magnet Synchronous Motor Stator Winding Fault Modelling
Typ
článek ve sborníku ve WoS nebo Scopus
Jazyk
angličtina
Originální abstrakt
This paper deals with the open-phase fault and the winding inter-turn short circuit fault modelling of 3-phase interior (salient pole) permanent magnet synchronous motor (IPMSM). We found out that these are the most frequent non-mechanical failures in IPMSM drives. This paper is focused on mathematical model and Matlab/Simulink model of such drive. The stationary reference frame is used for representation of a model, according to the stator winding asymmetry (caused by fault in one phase winding). Model with faults is built on SimScape Matlab/Simulink toolbox. The results indicate that this is powerful way how to simulate complex electromechanical system in non-standard operational regime. It suggests that this model can be used for verifying the fault detection algorithms based on the stator current signature analysis or the state observers.
Klíčová slova
Interior permanent magnet synchronous motor (IPMSM), open phase fault, inter-turn short circuit, insulation failure, mathematical model, Simulink model, SimScape
Autoři
OTAVA, L.; BUCHTA, L.; GRAF, M.
Rok RIV
2015
Vydáno
13. 5. 2015
ISSN
1474-6670
Periodikum
Programmable devices and systems
Ročník
48
Číslo
4
Stát
Spojené království Velké Británie a Severního Irska
Strany od
324
Strany do
329
Strany počet
6
BibTex
@inproceedings{BUT114150, author="Lukáš {Otava} and Luděk {Buchta} and Miroslav {Graf}", title="Interior Permanent Magnet Synchronous Motor Stator Winding Fault Modelling", booktitle="13th IFAC Conference on Programmable Devices and Embedded Systems - PDeS 2015", year="2015", journal="Programmable devices and systems", volume="48", number="4", pages="324--329", issn="1474-6670" }