Detail publikace

Degradation Mechanisms in the Lead Acid Battery Causing Premature Capacity Loss

ZIMÁKOVÁ, J. VACULÍK, S. FRYDA, D. BAČA, P.

Originální název

Degradation Mechanisms in the Lead Acid Battery Causing Premature Capacity Loss

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

angličtina

Originální abstrakt

There are several types of degradation mechanisms in the lead-acid battery, according to the type and duration. Usually there isn’t only one type but more, depending on how is battery loaded. Influence of degradation mechanisms cannot be eliminated. However, there are methods to minimize undesirable phenomena. Using of these methods is allowed only in specific regime. Another approach to this problem is manufacturing special accumulators for specific applications. But even in this case it is necessary compromise.

Klíčová slova

degradation mechanism, lead-acid battery, aplication

Autoři

ZIMÁKOVÁ, J.; VACULÍK, S.; FRYDA, D.; BAČA, P.

Rok RIV

2015

Vydáno

16. 12. 2015

Nakladatel

ECS

Místo

USA

ISBN

978-80-214-5109-4

Kniha

ESC Transaction

ISSN

1938-5862

Periodikum

ECS Transactions

Ročník

2015

Číslo

70

Stát

Spojené státy americké

Strany od

21

Strany do

25

Strany počet

5

URL

BibTex

@inproceedings{BUT119398,
  author="Jana {Zimáková} and Sebastian {Vaculík} and Daniel {Fryda} and Petr {Bača}",
  title="Degradation Mechanisms in the Lead Acid Battery Causing Premature Capacity Loss",
  booktitle="ESC Transaction",
  year="2015",
  journal="ECS Transactions",
  volume="2015",
  number="70",
  pages="21--25",
  publisher="ECS",
  address="USA",
  doi="10.1149/07001.0021ecst",
  isbn="978-80-214-5109-4",
  issn="1938-5862",
  url="http://ecst.ecsdl.org/content/70/1/21.abstract"
}