Detail publikace

Low temperature surface cooling

HNÍZDIL, M. CHABIČOVSKÝ, M.

Originální název

Low temperature surface cooling

Typ

souhrnná výzkumná zpráva - smluv. výzkum

Jazyk

angličtina

Originální abstrakt

Fives Stein uses a cooling technology based on both side water spray for continuous annealing or galvanizing line. The aim of this project was to standardize or improve this cooling technology. Spray cooling visualizations were done first. Second, several spraying configuration were tested in order to study the influence of these parameters on the heat transfer coefficient. They were: spray distance, nozzle span, nozzle inclination angle, cooling header span, water pressure and nozzle type. Vertically moving testing bench was used for these tests. Results showed significant influence of some tested parameters on heat transfer coefficient. These results were sent to Fives Stein company and they will decided about cooling system improvements with respect to the costs.

Klíčová slova

Spray cooling, galvanizing line, heat transfer coefficient, strip cooling

Autoři

HNÍZDIL, M.; CHABIČOVSKÝ, M.

Vydáno

23. 10. 2015

Strany od

1

Strany do

34

Strany počet

34

BibTex

@misc{BUT123520,
  author="Milan {Hnízdil} and Martin {Chabičovský}",
  title="Low temperature surface cooling",
  year="2015",
  pages="1--34",
  note="summary research report - contract. research"
}