Detail publikace

Light Flicker of Fluorescent Lamps with Different Types of Ballasts Caused by Interharmonics

DRÁPELA, J. KRÁTKÝ, M. WEIDINGER, L. ZÁVODNÝ, M.

Originální název

Light Flicker of Fluorescent Lamps with Different Types of Ballasts Caused by Interharmonics

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

angličtina

Originální abstrakt

The paper presents an analysis of the voltage fluctuations caused by interharmonics and its influence on luminous flux fluctuations of used combinations of fluorescent lamps and ballasts. One of the analysis results is a concept determining light sources sensitivity to such disturbing type based on frequency components utilization. Further a complex measured data file of sensitivity curves in various combinations of fluorescent lamps and ballasts are pointed. Measured and compared combinations include various types of fluorescent lamps, various wattages, modes of operation of the ballast and its specific designs and dimensioning of circuit elements etc.

Klíčová slova

Ballast Types, Flicker Curve, Gain Factor, Interharmonics, Light Flicker, Voltage Fluctuation

Autoři

DRÁPELA, J.; KRÁTKÝ, M.; WEIDINGER, L.; ZÁVODNÝ, M.

Rok RIV

2005

Vydáno

27. 6. 2005

Nakladatel

IEEE PES

Místo

St. Petersburg

ISBN

978-5-93208-034-4

Kniha

IEEE PowerTech 2005 Conference Proceedings

Číslo edice

1

Strany od

1

Strany do

7

Strany počet

7

URL

BibTex

@inproceedings{BUT12658,
  author="Jiří {Drápela} and Milan {Krátký} and Libor {Weidinger} and Michal {Závodný}",
  title="Light Flicker of Fluorescent Lamps with Different Types of Ballasts Caused by Interharmonics",
  booktitle="IEEE PowerTech 2005 Conference Proceedings",
  year="2005",
  number="1",
  pages="1--7",
  publisher="IEEE PES",
  address="St. Petersburg",
  isbn="978-5-93208-034-4",
  url="http://www.sei.irk.ru/PowerTech2005/abstr.html"
}