Originální abstrakt

The authors describe the basics of the CIP protocol, show measures to ensure the CIP protocol safety in the transmission of safety-related information, and compare the classic data package with the CIP-Safety information transported over Ethernet. This article indicates that Ethernet can be used to transfer safety information even for the highest safety integrity level, and it also points out that network is not a critical factor in designing safety functions. Further, the paper contains calculation of failure probability per hour for the communicated data, which can be taken into account when users design distributed safety functions.

Klíčová slova

Safety; Communication Protocol; CIP; Ethernet

Autoři

ŠTOHL, R.; STIBOR, K.

Vydáno

27. 6. 2016

Nakladatel

Institute of Electrical and Electronics Engineers Inc.

Místo

Tatranska Lomnica

ISBN

978-1-4673-8606-7

Kniha

Proceedings of the 2016 17th International Carpathian Control Conference, ICCC 2016

Strany od

729

Strany do

734

Strany počet

6

BibTex

@inproceedings{BUT127433,
  author="Radek {Štohl} and Karel {Stibor}",
  title="Cascading safety relays compared to using a network solution",
  booktitle="Proceedings of the 2016 17th International Carpathian Control Conference, ICCC 2016",
  year="2016",
  pages="729--734",
  publisher="Institute of Electrical and Electronics Engineers Inc.",
  address="Tatranska Lomnica",
  doi="10.1109/CarpathianCC.2016.7501191",
  isbn="978-1-4673-8606-7"
}