Originální název
Influence of mesh density on calculated extreme stresses in aortic aneurysms
Typ
článek v časopise ve Scopus, Jsc
Jazyk
angličtina
Originální abstrakt
The paper deals with evaluation of the influence of finite element mesh density on the resulting extreme stresses in models of abdominal aortic aneurysms. In most patient-specific computational models published recently, a free mesh of tetrahedrons is used and any information on density of the applied mesh is often missing. In this study a comparison of different mesh densities has been realized with four patient-specific model geometries, all based on a numerical reconstruction of the unloaded geometry of the aneurysm, and with two different Yeoh-type constitutive models. It has been shown that resulting maximum stresses are not mesh independent; due to a better description of the stress gradient in the critical location, the maximum wall stress increases with increasing number of elements throughout the wall thickness, especially in models without residual stresses. This effect is more pronounced when using Vande Geest constitutive model with higher strain stiffening than for Raghavan-Vorp material parameters. Although the mesh density requirements were not so high when the stress gradient was reduced by taking residual stresses into consideration, even in this case low numbers of elements throughout the wall thickness may give mesh dependent results. Although for a rigorous recommendation of the mesh density more analyses are needed, it was shown that the time consuming procedure of taking residual stresses into consideration cannot be replaced by a simpler model with rough mesh.
Klíčová slova
abdominal aortic aneurysm; finite element model; peak wall stress; mesh density
Autoři
MAN, V.; POLZER, S.; BURŠA, J.
Vydáno
12. 12. 2016
Nakladatel
University of West Bohemia
Místo
Pilsen
ISSN
1802-680X
Periodikum
Applied andComputational Mechanics
Ročník
10
Číslo
2
Stát
Česká republika
Strany od
97
Strany do
110
Strany počet
14
URL
https://www.kme.zcu.cz/acm/acm/article/view/327
Plný text v Digitální knihovně
http://hdl.handle.net/11012/204350
BibTex
@article{BUT131626, author="Vojtěch {Man} and Stanislav {Polzer} and Jiří {Burša}", title="Influence of mesh density on calculated extreme stresses in aortic aneurysms", journal="Applied andComputational Mechanics", year="2016", volume="10", number="2", pages="97--110", issn="1802-680X", url="https://www.kme.zcu.cz/acm/acm/article/view/327" }