Detail publikace

ANALYSIS OF BROKEN ROTOR BARS FAULT IN INVERTER FED INDUCTION MOTOR BY MEANS OF MOTOR CURRENT SIGNATURE ANALYSIS AND STRAY FLUX OF MOTOR

CHERNYAVSKA, I.

Originální název

ANALYSIS OF BROKEN ROTOR BARS FAULT IN INVERTER FED INDUCTION MOTOR BY MEANS OF MOTOR CURRENT SIGNATURE ANALYSIS AND STRAY FLUX OF MOTOR

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

angličtina

Originální abstrakt

In this paper the analysis of effect of broken rotor bar fault in squirrel-cage induction motor fed by frequency converter is presented. The motor current signature analysis as well as stray flux of motor were used in order to verify the capability of these techniques to identify the presence of different types of investigated fault in case of different types of supply and load. There were measured 4-pole motors with different level of broken rotor bar fault under different loads. Obtained data is presented in the form of graphs and tables and the comparison of obtained results was carried out.

Klíčová slova

squirrel-cage induction motor fault; motor current signature analysis; stray flux; broken rotor bars; inverter; fault diagnosis; condition monitoring

Autoři

CHERNYAVSKA, I.

Vydáno

27. 4. 2017

Nakladatel

Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií

Místo

Brno, Czech Republic

ISBN

978-80-214-5496-5

Kniha

Proceedings of the 23rd Conference STUDENT EEICT 2017

Edice

1

Strany od

593

Strany do

597

Strany počet

5

BibTex

@inproceedings{BUT141661,
  author="Ielyzaveta {Chernyavska}",
  title="ANALYSIS OF BROKEN ROTOR BARS FAULT IN INVERTER FED INDUCTION MOTOR BY MEANS OF MOTOR CURRENT SIGNATURE ANALYSIS AND STRAY FLUX OF MOTOR",
  booktitle="Proceedings of the 23rd Conference STUDENT EEICT 2017",
  year="2017",
  series="1",
  pages="593--597",
  publisher="Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií",
  address="Brno, Czech Republic",
  isbn="978-80-214-5496-5"
}