Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikace
CHERNYAVSKA, I.
Originální název
ANALYSIS OF BROKEN ROTOR BARS FAULT IN INVERTER FED INDUCTION MOTOR BY MEANS OF MOTOR CURRENT SIGNATURE ANALYSIS AND STRAY FLUX OF MOTOR
Typ
článek ve sborníku ve WoS nebo Scopus
Jazyk
angličtina
Originální abstrakt
In this paper the analysis of effect of broken rotor bar fault in squirrel-cage induction motor fed by frequency converter is presented. The motor current signature analysis as well as stray flux of motor were used in order to verify the capability of these techniques to identify the presence of different types of investigated fault in case of different types of supply and load. There were measured 4-pole motors with different level of broken rotor bar fault under different loads. Obtained data is presented in the form of graphs and tables and the comparison of obtained results was carried out.
Klíčová slova
squirrel-cage induction motor fault; motor current signature analysis; stray flux; broken rotor bars; inverter; fault diagnosis; condition monitoring
Autoři
Vydáno
27. 4. 2017
Nakladatel
Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií
Místo
Brno, Czech Republic
ISBN
978-80-214-5496-5
Kniha
Proceedings of the 23rd Conference STUDENT EEICT 2017
Edice
1
Strany od
593
Strany do
597
Strany počet
5
BibTex
@inproceedings{BUT141661, author="Ielyzaveta {Chernyavska}", title="ANALYSIS OF BROKEN ROTOR BARS FAULT IN INVERTER FED INDUCTION MOTOR BY MEANS OF MOTOR CURRENT SIGNATURE ANALYSIS AND STRAY FLUX OF MOTOR", booktitle="Proceedings of the 23rd Conference STUDENT EEICT 2017", year="2017", series="1", pages="593--597", publisher="Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií", address="Brno, Czech Republic", isbn="978-80-214-5496-5" }